  Ontario Building Code Minimum Requirements Dor Ann Standard EnergyStar
Best in Class
Upgrade
EnergyStar + Domestic Hot Water Upgrade
 
BASEMENT WALLS R-8 2ft below grade R-12 full height R-12 full height R-12 full height
CONCRETE SLAB uninsulated uninsulated - -
MAIN WALLS R-17.5 R-17.5 R-20 R-20
ATTIC R-32 R-40 R-51 R-51
WINDOWS metal TP 1/2" air space vinyl 1/2" airspace Low EE Argon Low EE Argon
HEATING 80% eff. 90% eff. 94% eff. 94% eff.
HOT WATER conventional 57% conventional 57% conventional 57% instantanous 82%
VENTILATION exhaust fans only exhaust fans only HRV 66% eff. HRV 66% eff.
ELECTRICAL CREDITS n/a n/a 1000 kwh 1000 kwh
AIR LEAKAGE estimated 5.5 ACH estimated 5.5 ACH required 2-3 ACH required 2-3 ACH
 
GREEN HOUSE GAS EMISSIONS
* one tonne (1000kg) is roughly the amount of pollution it would take to fill a hockey arena
12313 kg 10490 kg 9340 kg 8679 kg
ENERGUIDE RATING
* each point on the EnerGuide scale ( 0-100 ) represents a 3-5% energy savings
68 75 min. 80 81
ESTIMATED ANNUAL ENERGY SAVINGS OVER A CODE BUILT HOME   $728.30 $1,198.86 $1,347.50